OPTIPOWER TORQUEMETERS download PDF

 

OPTIPOWER FOR SHAFT TORQUE, THRUST, SPEED & POWER FOR PROPULSION PLANT PERFORMANCE !

 

OPTIPOWER SYSTEM SPECIFICATIONS
Sensor Input:
                Full Bridge strain gage (4 active arms (Full compensation). 350U standard;
Bridge Excitation:
                5 VDC, Regulated
Sensor Range:
                ±500 microstrain (Full Bridge, 4 active arms - Torque)
                ±769 microstrain (Full Bridge, 4 active arms - Thrust)
                Other microstrain ranges are available
Temp Coefficient - Gain:
                ≤ 0.005% FS/°C (50 ppm/°C) +20°+70°C
                ≤ 0.010% FS/°C(100 ppm/°C) -40°+85°C
Temp Coefficient - Zero:
                ≤ 0.005% FS/ºC (50 ppm/°C) +20°+70°C
                ≤ 0.010% FS/ºC (100 ppm/°C) -40°+85°C
Linearity:
                ≤ 0.05% FS
G-force Rating:
                Bigger than 3000 g's. For example, 5700 rpm on 102 mm shaft.
Sensor Connection:
                4-conductor cable

ROTATING COLLAR (shaft diameter to be specified by customer)

Material:
                Cast nylon standard
Assembly:
                Split collar bolts together onto shaft.

MASTER CONTROL UNIT & POWER COIL

Receiver Output Signal:
                Four independent current output signals:
                               1. Torque: 12 ± 8 mA, scalable
                               2. Power: 12 ± 8 mA, scalable
                               3. Shaft Speed/RPM: Pulse Indicator, 5-19 mA
                               4. Shaft Direction: Binary Indicator, 5 or 19 mA
                               5. NEMA protocol
                               6. RS 485
Receiver Input Power:
                11-16 VDC standard; 2A max, 0.5A nominal
                (115VAC or 230VAC or 24 VDC option available)
Dimensions:
                Master Control Unit: 152 x 152 x 102 mm
                Power Coil - Outer Diameter: same as Rotating Collar OD
                Width: 3 mm

OPTIPOWER SYSTEM

Resolution:
                14 bits (16384 points of resolution)
Noise Level:
                < 0.10% RMS FS
Frequency Response: (Torque and Power)
                Switch selectable: 1000 Hz, 12 Hz, 1.5 Hz or 0.1 Hz
                (-3dB frequency, typical)
Sampling Rate:
                4800 Hz
Operating Temperature:
                -40°+85°C
                0% to 90% relative humidity, non condensing

Contact Us!

© 2011 Tecnoveritas. Web Design by Web Colinas